Backups, handover and exports
The timetable cannot be written
Timetables run on a network gateway, not on the PC.
Messages this article covers
No gateway found on the network. Connect the gateway or display to the same network as this computer.
This gateway's firmware has no timetable function.
This gateway drives … DALI lines. A timetable written here would reach all of them, so Lumcue does not write it.
The gateway's clock is not set or is wrong.
The gateway has no location, so sunrise and sunset times are unknown.
Line … already uses this gateway for its timetable. Each line needs its own gateway.
Why. A timetable (shop opening, signs off, evening window) must run when the PC is gone. Lumcue writes it into a Lunatone DALI-2 IoT gateway or Display on the line.
What to check.
- The gateway and the PC are on the same network.
- The firmware has the timetable function: DALI-2 IoT or Display 1.14 or newer.
- Each line has its own gateway. Lumcue does not write a timetable to a gateway that drives several lines.
- Set the gateway's clock and location on its own web page (the app gives the address), so sunrise and sunset work.
- Click Check timetable first, then Write timetable.
The gateway connection is beta. Check the next 24 hours of entries on site.
Still stuck?
In the app, open Settings > Diagnostics > Send to Lumcue support and copy the ticket code. Then write to support@lumcue.com with the code, the time, the exact message and what you were doing.