Scenes are one of the most useful features in a DALI installation, and one of the most often misused. A well-planned scene structure lets a building manager set a meeting room for a presentation or a restaurant for evening service at the touch of a button. A poorly planned one leaves end users with inconsistent buttons, missing levels and a system nobody wants to touch after handover.

This guide covers practical scene programming for installers and electrical contractors, from tidy office presets to layered hospitality moods.

How DALI Scenes Actually Work

Before planning scenes, it helps to understand where they live and how they are recalled.

Scenes are stored in the control gear

In DALI, configuration data such as scene values, fade times and group assignments is stored in the electronic control gear itself, not in a central controller [6]. When a scene is recalled, each driver looks up its own stored value for that scene and moves to it.

This has several practical consequences:

  • Distributed resilience. The lighting behaviour sits in the drivers, so scene recall does not depend on a central controller holding the level tables.
  • Replacement drivers need attention. A new driver will not automatically know the scene values of the one it replaces. Your handover documentation needs to make re-commissioning straightforward.
  • Backups matter. Because the data is spread across many devices, keep an exported record of the configuration rather than relying on memory.

One command, many individual levels

Each item of control gear has 16 scenes, and a single GO TO SCENE command can instruct all the lights, or any combination of them, to go to individually pre-defined levels and/or colours [1]. This is the key difference between a scene and a group command. A group command sends the same instruction to every member, whereas a scene lets every luminaire respond with its own stored value.

That is why scenes are ideal for creating a "look" across a space: downlights low, wall washers higher, feature lighting at a particular colour, all from one command.

Know Your Limits Before You Design

Good scene design starts with the constraints of the bus.

  • A DALI line supports up to 64 individually addressed units, 16 groups and 16 scenes [5].
  • A subnet supports 64 control gear addresses and 64 control device addresses, such as sensors and push buttons [2].
  • Each DALI device can be assigned to up to 16 groups and 16 scenes [7].

The scene limit is the one that most often catches people out on larger projects. If you allocate scenes casually on a busy line, perhaps one set for the meeting room and another for the open-plan area, you can run out of slots before the client's wish list is complete. Plan the scene map for the whole line, not room by room.

Plan Scenes Before You Programme Them

Build a scene register

Before touching the commissioning software, create a simple scene register for each line. For every scene slot, record:

  • The scene name in plain language (for example "Presentation" or "Late Dining")
  • Which areas and luminaires take part
  • The intended level and/or colour for each participating luminaire
  • The intended fade behaviour
  • Which control devices recall it

This document becomes the backbone of your commissioning and your handover pack.

Use consistent numbering across the building

Where possible, give the same scene slot the same meaning across every comparable space. If "Presentation" occupies the same slot in every meeting room, panels, schedules and building management integrations become far easier to configure and maintain. Consistency also helps facilities staff, who will quickly learn what each button does.

Remember non-participating luminaires

Not every luminaire on a line needs to respond to every scene. Luminaires that should be unaffected by a scene must be configured so they ignore it, rather than being left with whatever value they happen to hold. Verify this during testing, particularly when areas share a line.

Office Presets: Function First

Office scenes should be functional, predictable and few in number. Users want the right light for the task, not a menu of options.

Typical office scene set

A practical meeting room or office scene set might include:

  • Full / General – normal working light for the space
  • Presentation – reduced light near the screen, with lighting maintained over the table for note-taking
  • Video Call – balanced lighting on faces and reduced glare behind participants
  • Cleaning / Maintenance – a utilitarian setting for out-of-hours use

Match scenes to the user interface

The number of scenes you offer should match the controls on the wall. A 4-scene push-button panel, such as Helvar's 935 with backlit scene-selection buttons and identification labels [8], suits a room with a small, clear set of presets. Labelled buttons remove the guesswork, so make sure the label text matches the scene names in your register.

Avoid programming more scenes than the user can reach. Hidden scenes that only exist in the software tend to be forgotten, then accidentally overwritten during later works.

Coordinate with sensors

In offices, scenes often coexist with presence and daylight sensors. Agree with the client how they should interact. For example, should a manually selected scene hold until the room is vacated, or should daylight control continue to adjust levels? Documenting this behaviour prevents a common complaint: "the lights keep changing on their own".

Hospitality Moods: Atmosphere and Transitions

Hospitality projects ask more of scenes. Restaurants, bars and hotels use lighting to shape how a space feels across the day, so atmosphere and transitions matter as much as levels.

Design around the day

A restaurant scene set often follows service periods:

  • Breakfast – bright and fresh
  • Lunch – comfortable general lighting
  • Evening – lower ambient light with emphasis on tables and features
  • Late / Bar – intimate, with accent lighting doing most of the work
  • Cleaning / Close – practical light for staff

Use individual levels and colours to layer the look

Because one scene command can send each luminaire to its own level and/or colour [1], you can build layered moods without complex logic. Ambient downlights, wall washers, feature pendants and colour-capable accent fittings can each take a different value within the same scene. Work through each layer separately during commissioning, then review the space as a whole with the client or interior designer present.

Pay attention to fades

Fade times are stored in the control gear alongside scene values [6], and in hospitality they are part of the experience. An abrupt jump from the lunch scene to the evening scene can be jarring for guests. Agree fade behaviour with the operator and test transitions while the space is in a realistic state, not just with the lights viewed in isolation.

Keep operator controls simple

Front-of-house staff should not need training to set the mood. Give them a small number of clearly labelled scenes and keep more specialised settings, such as event or cleaning modes, on separate or restricted controls.

Standards and Interoperability

Scenes are defined within the DALI standards, and staying current helps avoid surprises on mixed-manufacturer projects. IEC 62386-102:2022, the third edition, covers digitally controlled control gear and replaces the 2014 edition and Amendment 1:2018 [3]. DALI Edition 2 brought more detailed Parts 101 and 102 and added a separate standard for control devices, Part 103 [4], which is relevant when push buttons and sensors from different suppliers recall scenes on the same bus.

Testing and Handover

Test every scene from every control

Recall each scene from every control device that is meant to trigger it. Check that participating luminaires reach the intended level or colour, that non-participating luminaires are unaffected, and that fades behave as agreed.

Document for the next person

Because scene data lives in the drivers [6], your scene register and an exported configuration are essential for future maintenance. Include them in the handover pack, together with panel labelling and any agreed sensor interactions.

Walk the client through it

A short walkthrough, button by button, catches mismatched expectations before they become call-backs.

FAQ

How many scenes can a DALI luminaire store?

Each item of DALI control gear has 16 scenes [1], and each device can be assigned to up to 16 scenes [7].

Where are DALI scene settings stored?

Scene values and fade times are stored in the electronic control gear itself, not in a central controller [6]. Keep a documented backup so replacement drivers can be reprogrammed.

What is the difference between a scene and a group?

A group command sends the same instruction to all members. A scene recall lets each luminaire go to its own pre-defined level and/or colour from a single command [1].

How many scenes should I put on a wall panel?

Match scenes to the user interface. A 4-scene panel with labelled, backlit buttons [8] suits spaces with a small set of clear presets. Avoid programming scenes users cannot reach.

Why plan scenes across the whole line rather than room by room?

A DALI line supports up to 16 scenes [5], so allocating them room by room can exhaust the available slots. A line-wide scene register keeps numbering consistent and avoids conflicts.